Fujian Shengtong Electrical Machinery Co.,Ltd.
|
|
| |
|
|
|
|

|

|
Click to enlarge image
|
Model Number |
generating sets |
THE FORMATION INSTRUCTION OF DIESEL GENERATING SETS 1.Diesel generating sets all diesel generating sets include diesel engine, alternator and control box . 2. Starting method of gen-sets. a).manual switch b).automatic starting wholly: when electric supply has been stopped, the gen-sets can start three times automatically in 3-28 seconds (time can be adjustable) between electric supply and everytime need 6-8 seconds. It will spend 12 seconds to accept load when electric supply is resumed, gen-set will maintain 23-230 seconds, then closes down automatically. 3.Control system apparatus: voltmeter, frequency meter, amperage meter, voltmeter of battery, meter of water temp., oil meter. control section: starting handler, key type switch, inductive type self-protection switch, and indicator. ADDITIONAL EQUIPMENTS 1.Automatic starting control panel this panel includes manual control panel, time relay, indicator testing button, alarm resetting button, over speed inductive switch, alarm buzzer of low-voltage of battery, starting malfunction alarm. 2.Automatic changing-over panel When the electric supply has been stopped, the gen-sets will start automatically. when the electric supply has been remended, the gen-sets will halt automatically. 3.Automatic diesel generating sets with intelligence performance . 4.Booster, battery charger, alarm buzzer, attached inductive protection switcher. 5.Trailer-behind movable power station. 6.Soundproof diesel generating sets. OTHER MAIN PERFORMANCE: 1.Voltage stead-state regulation ±1% fluctuation 1.5% Transient-stateregulation -15~20% stead time 5s Frequency Stead-state regulation 5% fluctuation ratio 1.5% Transient-state regulation ±10% stead time 5s 2.The noise of gen-sets should no more than 85db(a). The fuel consumption is no more than 2.5kg/kw.h. Remarks: all the diesel engine have been made in china |
My email/MSN: trading_dennis AT hotmail.com
TECHNICAL DATA
|
GEN-SETS MODEL
|
RATED OUTPUT(KW) |
RATED CURRENT (A) |
FUEL CONSUMPTION (g/kw.h) |
STARTING METHOD |
ENGINE MODEL |
DIMENSIONS (mm) |
N.W. (kg) |
| GF2-10kW |
10 |
18.1 |
<257
|
12V D.C ELECTRIC |
295AD |
1380×640×1000 |
600 |
| GF2-12kW |
12 |
21.6 |
295AD |
1380×640×1000 |
600 |
| GF2-15kW |
15 |
27 |
395AD |
1640×650×980
|
650 |
| GF2-20kW |
20 |
36 |
495AD |
1780×750×1000 |
750 |
| GF2-24kW |
24 |
43.3 |
495AD |
1780×750×1000 |
780 |
| GF2-30kW |
30 |
54.1 |
495AZD |
1820×750×1000 |
920 |
| GF2-40kW |
40 |
72.1 |
<238 |
24V D.C ELECTRIC |
4135D |
2200×710×1900 |
1610 |
| GF2-50kW |
50 |
90.2 |
4135D |
2280×820×1350 |
1750 |
| GF2-64kW |
64 |
115.4 |
*4135D |
2400×850×1400 |
1800 |
| GF2-75kW |
75 |
135.3 |
*6135 |
2400×850×1400 |
2330 |
GF2-90kW
|
90 |
162.3 |
*6135D |
3000×900×1370 |
2500 |
| GF2-100kW |
100 |
180.3 |
*6135AD |
3000×900×1370
|
2650 |
| GF2-120kW |
120 |
216.5 |
238 |
*6135AZD |
3000×900×1370
|
2800 |
| GF2-150kW |
150 |
270.6 |
250
|
*12V135D |
3300×960×1650 |
3500 |
| GF2-200kW |
200 |
360.8 |
250
|
812V135AD |
3210×1320×1920 |
3750 |
| GF2-250kW |
250 |
451 |
250
|
*12V135D |
3210×1320×1920 |
3850 |
| GF2-300kW |
300 |
541.2 |
250 |
W12V135AZD-1 |
3300×1770×1905 |
4300 |
| GF2-320kW |
320 |
577.3 |
228 |
W12V135AZL |
3300×1770×1905 |
4350 |
* VOLTAGE:400/230V * ROTATION SPEED:1500/1800 r.p.m/min * COOLING METHOD: CLOSED CIRCULATION COOLING * FREQUENCY: 50Hz/60Hz *POWER FACTOR: 0.8 (LAG) * TRIPLE HARMONIC STC SERIES OR BRUSHLESS EXCITING OR TFW SERIES OF ALTERNATOR |
|
|
|
|
|
| |
|
|
|